Browse products

Showing 25–36 of 65 results

  • Activated carbon filter cartridge for NFIL/CA or FIL/60 filter housings to perform ZERO calibration on Chlorine controllers

    Quick View
    • 60 Micron Filtration
    • Replaceable Filter Cartridge part number: EMEC CA/60

     

    Specifications

     

     

    Max Pressure / Temp        5 bar @ 50°C

    Materials                              PP Body

    IP Rating                              IP65

    Install Kit Included             6x8mm tube

    Quick View
    • Low cost reliable probe
    • Smooth body, 12mm diameter
    • 0.8 Meter Cable with BNC

     

    Specifications

     

     

    Variables Measured pH
    Max Pressure / Temp 3.5 bar @ 80°C, 7 bar @ 70°C
    Process Connection 12mm Diameter Smooth Body
    IP Rating IP65
    Quick View
    • Free (Available) Chlorine Measurement for Sodium Hypochlorite
    • Self Cleaning
    • Probes available for measuring ranges of 0-2mg/L (SCL18/2) or 0-20mg/L (SCL18/20)
    • pH buffered with max 10% error per pH point
    • Temperature Compensated for 5-70°C Operation
    • 8 Bar Max Pressure
    • Range of 5-9 pH
    • Digital interface to controller, i.e auto sensor and range detect
    • EMEC SCL digital sensors compatible with EMEC LDSCLP Controllers
    • EMEC SVCL analog sensors compatible with EMEC LDSCL controllers
    • (EMEC SVCL sensors supersede EMEC ECL sensors)

     

    Specifications

     

     

    Variables Measured Cl2, Temperature
    Max Pressure / Temp 8 bar @ 70°C
    IP Rating IP65
    Interface Digital
    Quick View
    • Free (Available) Chlorine Measurement for Sodium Hypochlorite
    • Probes available for measuring ranges of 0-2mg/L (SCL3N/2), 0-10mg/L (SCL3N/10) or 0-20mg/L (SCL3N/20)
    • pH buffered with max 10% error per pH point
    • Temperature Compensated for 1-40°C Operation
    • 1 Bar Max Pressure
    • Max pH of 9
    • Digital interface to controller, i.e auto sensor and range detect
    • EMEC SCL digital sensors compatible with EMEC LDSCLP Controllers
    • EMEC SVCL analog sensors compatible with EMEC LDSCL controllers
    • (EMEC SVCL sensors supersede EMEC ECL sensors)

     

    Specifications

     

    Variables Measured Cl2, Temperature
    Max Pressure / Temp 0.5 bar @ 40°C
    IP Rating IP65
    Interface Digital
    Quick View
    • Total Chlorine Measurement
    • Probes available for measuring ranges of 0-2mg/L (SCL8/2) or 0-20mg/L (SCL8/20)
    • pH buffered with max 10% error per pH point
    • Temperature Compensated for 1-40°C Operation
    • 1 Bar Max Pressure
    • Max pH of 12
    • Digital interface to controller, i.e auto sensor and range detect
    • EMEC SCL digital sensors compatible with EMEC LDSCLP Controllers
    • EMEC SVCL analog sensors compatible with EMEC LDSCL controllers
    • (EMEC SVCL sensors supersede EMEC ECL sensors)

     

    Specifications

     

     

    Variables Measured Cl2
    Max Pressure / Temp 0.5 bar @ 40°C
    IP Rating IP65
    Interface Digital
    Quick View
    • Free (Available) Chlorine Measurement for Sodium Hypochlorite
    • Probes available for measuring ranges of 0-2mg/L (SVCL3N/2), 0-10mg/L (SVCL3N/10) or 0-20mg/L (SVCL3N/20)
    • pH buffered with max 10% error per pH point
    • Temperature Compensated for 1-40°C Operation
    • 1 Bar Max Pressure
    • Max pH of 9
    • Analogue interface to controller, i.e. voltage proportional to ppm
    • EMEC SCL digital sensors compatible with EMEC LDSCLP Controllers
    • EMEC SVCL analog sensors compatible with EMEC LDSCL controllers
    • (EMEC SVCL sensors supersede EMEC ECL sensors)

     

    Specifications

     

     

    Variables Measured Cl2, Temperature
    Max Pressure / Temp 0.5 bar @ 40°C
    IP Rating IP65
    Interface Analogue
    Quick View
    • Total Chlorine Measurement
    • Probes available for measuring ranges of 0-2mg/L (SVCL8/2) or 0-20mg/L (SVCL8/20)
    • pH buffered with max 10% error per pH point
    • Temperature Compensated for 1-40°C Operation
    • 1 Bar Max Pressure
    • Max pH of 12
    • Analogue interface to controller, i.e. voltage proportional to ppm
    • EMEC SCL digital sensors compatible with EMEC LDSCLP Controllers
    • EMEC SVCL analog sensors compatible with EMEC LDSCL controllers
    • (EMEC SVCL sensors supersede EMEC ECL sensors

     

    Specifications

     

     

    Variables Measured Cl2
    Max Pressure / Temp 0.5 bar @ 40°C
    IP Rating IP65
    Interface Analogue
    Quick View
  • WHY SCALESAFE?

    Used in the commercial water treatment industry for over 25 years to eliminate mineral buildup and corrosion. The technology can be used to
    protect your water system at a fraction of the cost of other water treatment systems

    Removes Existing Scale
    ScaleSafe removes and prevents scale build up throughout your water system, resulting in lower utility bills

    Prevents Corrosion
    ScaleSafe combines with the calcium carbonate in the water forming a protective film on the insides of pipes and water fed equipment which acts as a deterrent to corrosion and scale

    Cost Negative
    ScaleSafe requires no electricity, maintenance, or guesswork. It is virtually maintenance free

     

    THE PROBLEM: BASIC WATER SCALING

     

    Water is the universal solvent. It dissolves everything it comes in contact with, whether it is as “hard” as iron or as “soft” as acid rain in the air. The water we use is saturated with many dissolved minerals. The amount of dissolved minerals depends on the water source and the water chemistry such as pH, oxygen content, temperature and pressure. When water is heated, its ability to hold calcium carbonate (scale) in solution is decreased. As temperature increases, calcium carbonate will begin to come out of solution and form hard water scale deposits. This causes harmful scale deposits in boilers, water heaters and other water fed equipment.

    HOW CAN THIS BE SOLVED?

     

    SCALESAFE HARD WATER TREATMENT

     

    When introduced into the water, ScaleSafe works in three unique ways.

    1) ScaleSafe acts as a scale inhibitor by distorting the almost perfect cube shape of calcium carbonate as it precipitates out of solution. By distorting the uniform shape, it will not allow the calcium carbonate to build up (deposit) on itself. It will also over time remove existing scale in the system. Furthermore, it increases the solubility of scale causing minerals. This helps keep them in solution as opposed to depositing as scale.

    2) ScaleSafe sequesters iron and manganese preventing these minerals from forming oxides (rust) and precipitating out of solution, thus eliminating the red & black staining caused by iron & manganese.

    3) ScaleSafe combines with the calcium carbonate in the water forming a protective film on the insides of pipes and water fed equipment which acts as a deterrent to corrosion and scale. This microfilm does not increase in thickness as it is continually washed off and replaced.

     

    • Unit                                     SSH001
    • Water Treated                   24,600 litres
    • Line size                             3/4″
    • Water flow                          8-45 litres per minute
    • Maximum pressure          100 PSI
    • Maximum water temp      29.5°C
    • Refill cartridge                   SSR01

     

    Installation at a new home site

     

    Code SSH001

    ScaleSafe Refills available

    Code SSR01

    Quick View
  • The innovative WaterLink® Spin Touch® photometer does all your pool and spa water testing for you wherever you need it—in the field or in the store!
    Each sealed reagent disk contains the precise amount of reagent needed to run a complete series of tests in just 30 or 60 seconds.
    Simply fill a reagent disk with a water sample, place it in the meter, tap “start”, and all your vital tests are done automatically.

    In the field, the results are displayed on the touchscreen, then can be transferred to DataMate® Web software* to be instantly analyzed, providing step-by-step treatment instructions on your mobile device and test history storage in the cloud.

    In the store, the Spin Touch® is run directly from your computer using DataMate® Web or DataMate® 10 software*.
    The results are displayed right on your monitor with all records being kept in the cloud or on your hard drive.
    This is the most advanced system for precise use of wet chemistry methods ever produced!
    Now pool and spa analysts can achieve precision without time consuming test and clean-up procedures. This ground-breaking analysis system is so simple anyone can use it!
    No vials to fill, no prep time, no guessing!

     

    CLICK BELOW FOR THE BROCHURE

    https://www.lamotte.com/images/pdf/literature/LaMotteWaterLinkSpinTouchBrochure.pdf

     

     

    Quick View
  • Treated Water WaterLink® Spin Disk Series

    Tests 8 of the most important factors in 1 minute

    Free Chlorine                     0 – 15 ppm

    Total Chlorine                    0 – 15 ppm

    Combined Chlorine          0 – 15 ppm

    pH                                       6.4 – 10.0 pH

    Total Hardness                  0 – 70  gpg

    0 – 1200 ppm

    Total Iron                            0 – 6 ppm

    Copper                               0 – 6 ppm

    Total Alkalinity                  0 – 250 ppm

    NEW BIGGER PACKAGING COMING SOON 100 PER BOX

    Pack Size
    Box of 50 discs

    Code AWS13

    Quick View
  • Treated Water WaterLink® Spin Disk Series

    Tests 9 of the most important factors in just 2 minutes!

    pH                               4.5 – 8.6 pH

    Total Hardness         0 – 70 gpg  / 0 – 1,200 ppm

    Total Iron                   0 – 6 ppm

    Ferric Iron                  0 – 6 ppm

    Ferrous Iron              0 – 6 ppm

    Copper                       0 – 6 ppm

    Nitrate (NO³)             0 – 50 ppm

    Nitrate (NO²)             0 – 2 ppm

    Total Alkalinity          0 – 250 ppm

    NEW BIGGER PACKAGING COMING SOON 100 PER BOX

    Pack Size
    Box of 50 discs

    Code AWS21