Chlorine Control Systems

Showing 25–32 of 32 results

  • Activated carbon filter cartridge for NFIL/CA or FIL/60 filter housings to perform ZERO calibration on Chlorine controllers

    Quick View
    • 60 Micron Filtration
    • Replaceable Filter Cartridge part number: EMEC CA/60

     

    Specifications

     

     

    Max Pressure / Temp        5 bar @ 50°C

    Materials                              PP Body

    IP Rating                              IP65

    Install Kit Included             6x8mm tube

    Quick View
    • Low cost reliable probe
    • Smooth body, 12mm diameter
    • 0.8 Meter Cable with BNC

     

    Specifications

     

     

    Variables Measured pH
    Max Pressure / Temp 3.5 bar @ 80°C, 7 bar @ 70°C
    Process Connection 12mm Diameter Smooth Body
    IP Rating IP65
    Quick View
    • Free (Available) Chlorine Measurement for Sodium Hypochlorite
    • Self Cleaning
    • Probes available for measuring ranges of 0-2mg/L (SCL18/2) or 0-20mg/L (SCL18/20)
    • pH buffered with max 10% error per pH point
    • Temperature Compensated for 5-70°C Operation
    • 8 Bar Max Pressure
    • Range of 5-9 pH
    • Digital interface to controller, i.e auto sensor and range detect
    • EMEC SCL digital sensors compatible with EMEC LDSCLP Controllers
    • EMEC SVCL analog sensors compatible with EMEC LDSCL controllers
    • (EMEC SVCL sensors supersede EMEC ECL sensors)

     

    Specifications

     

     

    Variables Measured Cl2, Temperature
    Max Pressure / Temp 8 bar @ 70°C
    IP Rating IP65
    Interface Digital
    Quick View
    • Free (Available) Chlorine Measurement for Sodium Hypochlorite
    • Probes available for measuring ranges of 0-2mg/L (SCL3N/2), 0-10mg/L (SCL3N/10) or 0-20mg/L (SCL3N/20)
    • pH buffered with max 10% error per pH point
    • Temperature Compensated for 1-40°C Operation
    • 1 Bar Max Pressure
    • Max pH of 9
    • Digital interface to controller, i.e auto sensor and range detect
    • EMEC SCL digital sensors compatible with EMEC LDSCLP Controllers
    • EMEC SVCL analog sensors compatible with EMEC LDSCL controllers
    • (EMEC SVCL sensors supersede EMEC ECL sensors)

     

    Specifications

     

    Variables Measured Cl2, Temperature
    Max Pressure / Temp 0.5 bar @ 40°C
    IP Rating IP65
    Interface Digital
    Quick View
    • Total Chlorine Measurement
    • Probes available for measuring ranges of 0-2mg/L (SCL8/2) or 0-20mg/L (SCL8/20)
    • pH buffered with max 10% error per pH point
    • Temperature Compensated for 1-40°C Operation
    • 1 Bar Max Pressure
    • Max pH of 12
    • Digital interface to controller, i.e auto sensor and range detect
    • EMEC SCL digital sensors compatible with EMEC LDSCLP Controllers
    • EMEC SVCL analog sensors compatible with EMEC LDSCL controllers
    • (EMEC SVCL sensors supersede EMEC ECL sensors)

     

    Specifications

     

     

    Variables Measured Cl2
    Max Pressure / Temp 0.5 bar @ 40°C
    IP Rating IP65
    Interface Digital
    Quick View
    • Free (Available) Chlorine Measurement for Sodium Hypochlorite
    • Probes available for measuring ranges of 0-2mg/L (SVCL3N/2), 0-10mg/L (SVCL3N/10) or 0-20mg/L (SVCL3N/20)
    • pH buffered with max 10% error per pH point
    • Temperature Compensated for 1-40°C Operation
    • 1 Bar Max Pressure
    • Max pH of 9
    • Analogue interface to controller, i.e. voltage proportional to ppm
    • EMEC SCL digital sensors compatible with EMEC LDSCLP Controllers
    • EMEC SVCL analog sensors compatible with EMEC LDSCL controllers
    • (EMEC SVCL sensors supersede EMEC ECL sensors)

     

    Specifications

     

     

    Variables Measured Cl2, Temperature
    Max Pressure / Temp 0.5 bar @ 40°C
    IP Rating IP65
    Interface Analogue
    Quick View
    • Total Chlorine Measurement
    • Probes available for measuring ranges of 0-2mg/L (SVCL8/2) or 0-20mg/L (SVCL8/20)
    • pH buffered with max 10% error per pH point
    • Temperature Compensated for 1-40°C Operation
    • 1 Bar Max Pressure
    • Max pH of 12
    • Analogue interface to controller, i.e. voltage proportional to ppm
    • EMEC SCL digital sensors compatible with EMEC LDSCLP Controllers
    • EMEC SVCL analog sensors compatible with EMEC LDSCL controllers
    • (EMEC SVCL sensors supersede EMEC ECL sensors

     

    Specifications

     

     

    Variables Measured Cl2
    Max Pressure / Temp 0.5 bar @ 40°C
    IP Rating IP65
    Interface Analogue